Skip to main content

Посібник з підбору

Choose a model by boosting level, duty point, power supply and pipe size

Four steps decide most selections: the duty point, the water source, the power supply, and the control and power stage. The guide covers flows from 25 L/min to 500 L/min and heads from 25 m to 75 m, plus pipeline boosting for DC duty.

  1. 1

    Duty point — required head = lifting height + pipework loss + target outlet pressure (2 bar ≈ 20 m); match to a boosting level.

  2. 2

    Water source — mains or rooftop tank suits a standard booster; sump or well below the pump calls for self-priming ICP100F (8 m) or ICP106F (9 m); pH 6.5–8.5, particles below 0.2 mm; liquid max. 70 °C (55 °C for PYS-E/PYPZ-E), ambient max. 40 °C.

  3. 3

    Power supply — standard single-phase 170–250 V, 50/60 Hz (PB320EA 160–265 V); PYS-E/PYPZ-E customizable 110 V/60 Hz or 170–220 V.

  4. 4

    Control and power stage — ICP100F/ICP106F hold constant pressure across 10–30 m; 6 five-stage models (SPS-90, SPS90-3, SCS90P-3, SCS100P-3, ICP100A, ICP102-50); PB320EA has 3 power settings; dry-run, overload and fault alarm self-check.

By required flow and head

Maximum flow and maximum head from the catalog tables, with the duty each model covers. Select the model whose curve covers your duty point at the required outlet pressure.

Catalog duty range by model

ModelDutyMaximum flowMaximum headPower rangePower supplyPipe sizeQuote
MT24-25Pipeline boosting (DC 24 V)25 L/min (1.5 m³/h)25 m (82 ft)0.2 kW (0.27 HP)DC 24 V15 mmЗапросити пропозицію
ISC-200Pipeline boosting (DC 24 V)25 L/min (1.5 m³/h)25 m (82 ft)0.2 kW (0.27 HP)DC 24 V15 mmЗапросити пропозицію
ISC2-200Pipeline boosting (DC 24 V)25 L/min (1.5 m³/h)25 m (82 ft)0.2 kW (0.27 HP)DC 24 V15 mmЗапросити пропозицію
PB320EAStandard whole-house boosting46 L/min (2.8 m³/h)32 m (105 ft)0,09–0,14 кВт (3 налаштування потужності)160 - 265 V, 50/60 Hz3/4" (19 mm)Запросити пропозицію
Z400High-head whole-house boosting50 L/min (3.0 m³/h)40 m (131 ft)0.4 kW (0.55 HP)170 - 260 V, 50/60 Hz1" (25 mm)Запросити пропозицію
Z600High-head whole-house boosting50 L/min (3.0 m³/h)40 m (131 ft)0.55 kW (0.75 HP)170 - 260 V, 50/60 Hz1" (25 mm)Запросити пропозицію
SPS-90Standard whole-house boosting60 L/min (3.6 m³/h)32 m (105 ft)0.18 - 0.38 kW (0.25 - 0.5 HP)170 - 250 V, 50/60 Hz3/4" (19 mm)Запросити пропозицію
SPS90-3Standard whole-house boosting70 L/min (4.2 m³/h)45 m (148 ft)0,27–0,58 кВт (5-ступенева регульована)170 - 250 V, 50/60 Hz1" (25 mm)Запросити пропозицію
P800-3High-head whole-house boosting72 L/min (4.3 m³/h)56 m (184 ft)0.75 kW (1.0 HP)170 - 260 V, 50/60 Hz1" (25 mm)Запросити пропозицію
SCS90P-3Standard whole-house boosting75 L/min (4.5 m³/h)45 m (148 ft)0,24–0,47 кВт (5-ступенева регульована)170 - 250 V, 50/60 Hz1" (25 mm)Запросити пропозицію
PYS-EHigh-head whole-house boosting82 L/min (4.9 m³/h)56 m (184 ft)0.45 - 0.75 kW (0.6 - 1 HP)На замовлення: 110 В / 60 Гц або 170–220 В / 50 Гц або 60 Гц1" (25 mm)Запросити пропозицію
PYPZ-EHigh-head whole-house boosting85 L/min (5.1 m³/h)55 m (180 ft)0.45 - 0.75 kW (0.6 - 1 HP)На замовлення: 110 В / 60 Гц або 170–220 В / 50 Гц або 60 Гц1" (25 mm)Запросити пропозицію
ICP100FStandard whole-house boosting86 L/min (5.2 m³/h)38 m (125 ft)0.75 kW (1.0 HP)170 - 250 V, 50/60 Hz1" (25 mm)Запросити пропозицію
ICP106FStandard whole-house boosting86 L/min (5.2 m³/h)42 m (138 ft)0.75 kW (1.0 HP)170 - 250 V, 50/60 Hz1" (25 mm)Запросити пропозицію
ICP100AStandard whole-house boosting102 L/min (6.1 m³/h)38 m (125 ft)0.3 - 0.75 kW (0.4 - 1 HP)170 - 250 V, 50/60 Hz1" (25 mm)Запросити пропозицію
SCS100P-3High-head whole-house boosting165 L/min (9.9 m³/h)75 m (246 ft)0,55–1,5 кВт (5-ступенева регульована)170 - 260 V, 50/60 HzG 1.25" (32 mm)Запросити пропозицію
SG95High-head whole-house boosting178 L/min (10.7 m³/h)73 m (240 ft)0.55 - 1.5 kW (0.75 - 2 HP)170 - 260 V, 50/60 Hz1" / 1.25" (25 / 32 mm)Запросити пропозицію
ICP102-50High-flow whole-house boosting500 L/min (30.0 m³/h)28 m (92 ft)0.35 - 1.5 kW (0.48 - 2 HP)170 - 250 V, 50/60 Hz2" (51 mm)Запросити пропозицію

Проведіть таблицю вбік, щоб побачити всі стовпці.

170–250 V, 50/60 Hz standard, except PB320EA 160–265 V, SCS100P-3 / SG95 / Z400 / P800-3 170–260 V, P800/1500 motor 175–260 V; PYS-E/PYPZ-E customizable 110 V/60 Hz or 170–220 V; DC 24 V range with AC 110/220 V adapter.

15 mm: MT24-25, ISC-200, ISC2-200 · 19 mm (3/4"): SPS-90, PB320EA · 25 mm (1"): SPS90-3, SCS90P-3, P800-3, Z400, ICP100A, ICP100F, ICP106F, PYS-E, PYPZ-E, SG95-550A, SG95-550S, SG95-650S · 32 mm (1.25"): SCS100P-3, SG120B-1.1, SG120B-1.5 · 51 mm (2"): ICP102-50.

Suction lift: ICP100F 8 m; ICP106F 9 m; Z400 9 m; PB320EA 6 m; SCS90P-3 / SCS100P-3 / P800-3 7 m; SPS-90 / SPS90-3 / ICP100A 7 m. Not stated for SG95.

P800/1500 is a permanent magnet motor only, for pump manufacturers. See D group .

What to check before ordering

Duty point · water source · water quality · voltage · pipe size · environment · quantity/port.

Send the duty point and get a model recommendation

Share the required flow and head, the water uses on site, the voltage and frequency, and the order quantity. The export team will confirm the boosting level, the model, the power setting and the matching documents.

Запросити пропозицію
Продажі та експорт
cason@calliopepump.com
Післяпродажне обслуговування
corleone@calliopepump.com
Головний офіс
office@calliopepump.com
Телефон / WhatsApp
+86 178 0591 6566

Ми використовуємо cookie

Необхідні файли cookie забезпечують роботу сайту. Аналітичні файли cookie встановлюються лише після натискання «Прийняти». Якщо ви відхилите, аналітичні файли cookie встановлюватися не будуть. Повідомлення про cookie