2026 catalog · SG SERIES

SG95Permanent Magnet Centrifugal Pipe Pump

The SG95 page covers five in-line pipeline pumps, not one model. The SG95 trio runs on 1-inch ports: the plastic-impeller 550A (0.55 kW, 86 L/min, 42 m), and the stainless-impeller 550S (0.55 kW, 75 L/min, 51 m) and 650S (0.65 kW, 80 L/min, 60 m). The SG120B pair steps up to 1.25-inch ports: 1.1 kW at 164 L/min and 62 m, and 1.5 kW at 178 L/min and 73 m. All five share a stainless body, ceramic shaft and bearing, and 170–260 V wide voltage; none is self-priming.

Catalog model names on this page: SG95 · SG95-550A · SG95-550S · SG95-650S · SG120B-1.1 · SG120B-1.5.

Rated power
0.55 - 1.5 kW (0.75 - 2 HP)
Maximum flow
178 L/min
Maximum head
73 m
Power supply
170 - 260 V, 50/60 Hz
Catalog page
Page 10
Pipeline Pump Family5 Models 0.55–1.5 kWUp to 178 L/minUp to 73 m HeadStainless Body≤40 dB Ultra-Silent

Key benefits

SG95 Permanent Magnet Centrifugal Pipe Pump · data from the 2026 catalog and the model page.

  • Five models on one page — 0.55 to 1.5 kW, 42 to 73 m of head, 75 to 178 L/min — so the pipe-run duty picks its own size.
  • In-line pipeline form: the pump installs directly in the pipe run, with no separate pump bay.
  • Stainless impeller options (550S, 650S) against the plastic-impeller 550A, for buyers who want all-metal wetted parts.
  • SG120B models reach 178 L/min — the highest flow of any pipeline pump in the range — on 1.25-inch ports.

Uses at least 60% less energy than a same-power conventional fixed-speed pump at the same flow/head duty point under constant-pressure conditions.

The specification confirmed for an order is the one stated in the order confirmation.

Technical data

Same fields, units and order for every model. Fields that are not published in the catalog are omitted.

Electrical

Rated power
0.55 - 1.5 kW (0.75 - 2 HP)
Power supply
170 - 260 V, 50/60 Hz

Hydraulic

Maximum flow
178 L/min
Maximum head
73 m
Noise
≤ 40 dB

Construction and environment

Pump body and wetted parts
Stainless steel · Ceramic shaft and bearing
Motor type
Permanent magnet motor with integrated variable frequency drive
Liquid temperature range
5–70 °C
Ambient temperature range
0–40 °C

Model data

Values as published in the catalog table for this model range.

ModelPower (kW)Power (HP)Current (A)Qmax (L/min)Hmax (m)
SG95-550A0.550.753.98642
SG95-550S0.550.753.97551
SG95-650S0.650.874.58060
SG120B-1.11.11.57.516462
SG120B-1.51.521017873

Performance curve

Head against capacity as published in the catalog, with metric axes.

Performance curve · SG95Head against capacity, metric axes
0 m20 m40 m60 m80 m0 L/min50 L/min100 L/min150 L/min183 L/minCapacity Q (L/min)Head H (m)
SG95-550ASG95-550SSG95-650SSG120B-1.1SG120B-1.5

Working conditions

Operating limits and media conditions published for this model.

Ambient temperature
0–40 °C
Liquid temperature
5–70 °C
Max. working pressure
10 bar
Noise
≤ 40 dB

Overall dimension

All dimensions in millimetres unless stated otherwise. Dimension references Width a, Height b, Depth c, Port offset d are printed on catalog page 10.

ModelDimensionsWeight
SG95-550A
  • Inlet 1"
  • Outlet 1"
  • a 95 mm
  • b 273 mm
  • c 62 mm
  • d 81 mm
5.8 kg
SG95-550S
  • Inlet 1"
  • Outlet 1"
  • a 95 mm
  • b 249 mm
  • c 62 mm
  • d 81 mm
SG95-650S
  • Inlet 1"
  • Outlet 1"
  • a 95 mm
  • b 268 mm
  • c 62 mm
  • d 81 mm
SG120B-1.1
  • Inlet 1.25"
  • Outlet 1.25"
  • a 123 mm
  • b 351 mm
  • c 62 mm
  • d 88.5 mm
SG120B-1.5
  • Inlet 1.25"
  • Outlet 1.25"
  • a 95 mm
  • b 273 mm
  • c 62 mm
  • d 81 mm

Applications

In-line pipeline boosting for homes and small buildings — five sizes from 42 m to 73 m of head, all fitting the same pipe-run installation.

  • Whole-House Boosting
  • Rooftop Tank & Water Tower Boosting
  • HVAC circulation

Installation notes

Points that apply to this model, from the catalog and the site installation guidance.

  • Install the pump in a dry, ventilated position within the ambient range listed above, and follow the installation drawing on catalog page 10.

Package

Packing information published for this model.

SG95-550A
350 × 115 × 115 · 5.8 kg
SG95-550S
326 × 115 × 115
SG95-650S
350 × 115 × 115
SG120B-1.1
SG120B-1.5

Ordering information

Ordering information for the 2026 range.

MOQ and packaging
Minimum order quantity (MOQ): 50 units in kraft-paper cartons, with your brand label available. 300 units in color boxes, with the packaging layout designed entirely to your requirements.
Lead time
30 days
OEM / ODM
Supported: custom voltage and frequency builds, own brand nameplate and rating labels, and adapted carton and shipping marks.
Connection
1 in (25 mm) / 1.25 in (32 mm)

Warranty: 2 yearsWarranty and After-sales

Selection hints

How SG95 is positioned against the rest of the range.

  • Choose SG95-550A or 550S for a single dwelling on a tank outlet or rising main, and 650S where more head is needed.
  • Use SG120B-1.1 or 1.5 for higher flows up to 178 L/min on 1.25-inch pipework.
  • Keep the working pressure within 10 bar and the liquid between 5 and 70 °C.

Power supply and CE marking

Statements that apply to the range, published so buyers can quote them in their own files.

Power supply and certification for this model are listed in the technical data above. The range carries the CE marking for sale in the European Economic Area; the technical file was verified by ECM, Certificate No. 0P230414.FMEUN01.

Downloads

Datasheet, performance curve and dimension data, generated from the catalog data on this page.

  • Datasheet

    Model, key specifications, power stage data and packing details generated from the catalog data on this page.

  • Performance Curve

    Head and flow curve for this model, redrawn from the catalog axis ranges.

  • Dimension Data

    Dimension table for each model in the range, in millimetres and inches.

Working on an SG95 project? Send the duty point, market and volume and the export team will confirm the configuration.

Cookies: essential storage keeps the site working. Analytics cookies are set only after you click Accept. If you decline, no analytics cookies are set. Cookie Notice