In many Philippine homes, water runs from a cistern to an overhead tank, then feeds the house by gravity. The upstairs shower gets a weak stream because gravity alone cannot push enough pressure to the top floor. An inverter booster pump installed between the tank and the house fixes this by holding a pressure set point. This guide covers the three numbers for a multi-storey home — lift and head, simultaneous flow, and the pressure setting — then matches them to a model.
Modelos usados como ejemplos en este artículo: SCS100P-3 bomba multietapa de acero inoxidable de imán permanente y frecuencia variable and SPS90-3 bomba presurizadora vfd de imán permanente, ambos listados en el bombas presurizadoras multietapa de acero inoxidable monofásicas grupo.
Storeys and head: how high the water must go
Each storey adds roughly 3 m of lift, so a three-storey house has its highest shower about 9 m above the pump. Head is the lift plus the friction the pipes add plus the pressure the highest outlet needs, and 1 bar is about 10.2 m of water column. For a VFD booster, the outlet pressure is the constant-pressure set point, so the required head is the set point plus lift plus friction. If the pump is fed from a pressurised mains line rather than a tank, the inlet pressure counts toward the total and the pump only has to add the difference.
Simultaneous flow: count what runs at the same time
Flow is the volume the site must deliver at the same moment, not the total of everything connected. A three-storey house with four taps, two showers and a washing machine rarely runs them all at once, so size for the realistic peak: the outlets that are actually open together at the busiest time of day, for example two showers plus a kitchen tap.
Write the peak down in litres per minute. An inflated flow figure is the most common sizing mistake: it pushes the selection to a larger pump that then runs throttled, noisy and far from its best efficiency point.
Pressure setting: what the set point should be
The VFD holds the pressure set point by changing motor speed, so the set point is the pressure the highest outlet sees. Set it high enough to cover the top shower with margin, but no higher: extra pressure is turned into noise and wear rather than useful flow, and it stresses pipes and fittings. The installer sets the point on site against the duty the house actually needs, and it can be adjusted later if the household changes.
A pump running near its design duty is quieter and draws closer to its rated input than a pump throttled far from the curve. That is why the set point and the model are chosen together, not separately.
Model comparison: a worked example
Take a three-storey house whose peak demand is 40 L/min at 28 m of head. That is the duty point: 40 L/min, 28 m. Here is how three models compare against it, using their published Q-H curves.
- SPS-90, Etapa 5 (0.38 kW): la curva publicada va de 32 m con caudal cero a 0 m con 60 L/min, pasando por 25.9 m con 30 L/min y 15.9 m con 45 L/min. Con 40 L/min entrega unos 19 m — por debajo de los 28 m que necesita la casa. La SPS-90 no cubre este punto de trabajo.
- ICP100F (0.75 kW): la curva publicada va de 38 m con caudal cero a 10 m con 87 L/min, pasando por 32 m con 34 L/min y 29 m con 47 L/min. Con 40 L/min entrega unos 30.6 m — por encima de los 28 m requeridos, con aproximadamente 2.6 m de margen. La ICP100F cubre el punto de trabajo.
- SCS100P-3, Potencia 1 (0.55 kW): la más baja de sus cinco etapas de potencia ya alcanza 115 L/min con hasta 46 m de altura, y su curva de Potencia 5 pasa por unos 63 m con 40 L/min. Cubre el punto de trabajo con mucha más altura de la que necesita la casa, por lo que está sobredimensionada para este trabajo — la altura extra se estrangularía.
- Veredicto: la ICP100F es la adecuada. Cubre el punto de trabajo cerca del centro de su curva, mientras la SPS-90 no llega y la SCS100P-3 es más bomba de lo que la casa puede usar.
Voltage and water source checks
A pump that covers the duty point still fails if the site cannot power it or feed it. Philippine homes run on 220V / 60Hz, so confirm the nameplate voltage and frequency against the supply before ordering. Then check the water source: a pump fed from a cistern below the pump works on suction lift, so priming and dry-run protection matter, and the suction pipe should be short, fitted with a strainer and a non-return valve, and free of high points that trap air. If the source is an overhead tank above the pump, the inlet is flooded and suction lift does not apply.
Próximos pasos
Work through the selection guide for a shortlist, then open a model page for the full specification and the Q-H curve. Send the three numbers — flow, head and voltage — with the inquiry, and our team confirms the model and replies with a quotation.
¿Listo para especificar? Envíe su caudal, altura, alimentación eléctrica y diámetro de tubería a través del formulario de consulta , o escriba al equipo de exportación en WhatsApp .