تخطي إلى المحتوى الرئيسي

دليل المشتري

Inverter Booster Pumps for Multi-Storey Homes: Flow, Head and Pressure Setting

In many Philippine homes, water runs from a cistern to an overhead tank, then feeds the house by gravity — and the upstairs shower gets a weak stream. An inverter booster between the tank and the house fixes it.

بواسطة Calliope Pumps16 November 20265 دقائق قراءةحُدّث 2026-11-16راجعه فريق Calliope الهندسي
مضخة SCS100P-3 المعززة متعددة المراحل من الفولاذ المقاوم للصدأ

In many Philippine homes, water runs from a cistern to an overhead tank, then feeds the house by gravity. The upstairs shower gets a weak stream because gravity alone cannot push enough pressure to the top floor. An inverter booster pump installed between the tank and the house fixes this by holding a pressure set point. This guide covers the three numbers for a multi-storey home — lift and head, simultaneous flow, and the pressure setting — then matches them to a model.

الطرازات المستخدمة كأمثلة في هذه المقالة: SCS100P-3 مضخة متعددة المراحل من الفولاذ المقاوم للصدأ بمغناطيس دائم بتردد متغير and SPS90-3 مضخة معززة vfd بمغناطيس دائم، وكلاهما مدرج في معززات متعددة المراحل من الفولاذ المقاوم للصدأ أحادية الطور المجموعة.

Storeys and head: how high the water must go

Each storey adds roughly 3 m of lift, so a three-storey house has its highest shower about 9 m above the pump. Head is the lift plus the friction the pipes add plus the pressure the highest outlet needs, and 1 bar is about 10.2 m of water column. For a VFD booster, the outlet pressure is the constant-pressure set point, so the required head is the set point plus lift plus friction. If the pump is fed from a pressurised mains line rather than a tank, the inlet pressure counts toward the total and the pump only has to add the difference.

Simultaneous flow: count what runs at the same time

Flow is the volume the site must deliver at the same moment, not the total of everything connected. A three-storey house with four taps, two showers and a washing machine rarely runs them all at once, so size for the realistic peak: the outlets that are actually open together at the busiest time of day, for example two showers plus a kitchen tap.

Write the peak down in litres per minute. An inflated flow figure is the most common sizing mistake: it pushes the selection to a larger pump that then runs throttled, noisy and far from its best efficiency point.

Pressure setting: what the set point should be

The VFD holds the pressure set point by changing motor speed, so the set point is the pressure the highest outlet sees. Set it high enough to cover the top shower with margin, but no higher: extra pressure is turned into noise and wear rather than useful flow, and it stresses pipes and fittings. The installer sets the point on site against the duty the house actually needs, and it can be adjusted later if the household changes.

A pump running near its design duty is quieter and draws closer to its rated input than a pump throttled far from the curve. That is why the set point and the model are chosen together, not separately.

Model comparison: a worked example

Take a three-storey house whose peak demand is 40 L/min at 28 m of head. That is the duty point: 40 L/min, 28 m. Here is how three models compare against it, using their published Q-H curves.

  • SPS-90، المرحلة 5 (0.38 kW): يمتد المنحنى المنشور من 32 m عند تدفق صفر إلى 0 m عند 60 L/min، مرورًا بـ 25.9 m عند 30 L/min و15.9 m عند 45 L/min. وعند 40 L/min يسلّم نحو 19 m — دون 28 m التي يحتاجها المنزل. ولا تغطي SPS-90 نقطة التشغيل هذه.
  • ICP100F ‏(0.75 kW): يمتد المنحنى المنشور من 38 m عند تدفق صفر إلى 10 m عند 87 L/min، مرورًا بـ 32 m عند 34 L/min و29 m عند 47 L/min. وعند 40 L/min يسلّم نحو 30.6 m — فوق 28 m المطلوبة، بهامش نحو 2.6 m. وتغطي ICP100F نقطة التشغيل.
  • SCS100P-3، القدرة 1 (0.55 kW): تصل أدنى مراحل قدرتها الخمس بالفعل إلى 115 L/min عند ارتفاع يصل إلى 46 m، ويمر منحنى القدرة 5 بنحو 63 m عند 40 L/min. وتغطي نقطة التشغيل بارتفاع أكبر بكثير مما يحتاجه المنزل، فهي كبيرة جدًا لهذا التشغيل — إذ سيُخنق الارتفاع الزائد.
  • الحكم: ICP100F هو المناسب. فهو يغطي نقطة التشغيل بالقرب من منتصف منحنى، بينما تقصّر SPS-90 وتكون SCS100P-3 مضخة أكبر مما يستطيع المنزل استخدامه.

Voltage and water source checks

A pump that covers the duty point still fails if the site cannot power it or feed it. Philippine homes run on 220V / 60Hz, so confirm the nameplate voltage and frequency against the supply before ordering. Then check the water source: a pump fed from a cistern below the pump works on suction lift, so priming and dry-run protection matter, and the suction pipe should be short, fitted with a strainer and a non-return valve, and free of high points that trap air. If the source is an overhead tank above the pump, the inlet is flooded and suction lift does not apply.

الخطوات التالية

Work through the selection guide for a shortlist, then open a model page for the full specification and the Q-H curve. Send the three numbers — flow, head and voltage — with the inquiry, and our team confirms the model and replies with a quotation.

هل أنت مستعد للتحديد؟ أرسل التدفق والارتفاع ومصدر الطاقة وحجم الأنبوب عبر نموذج الاستفسار ، أو راسل فريق التصدير على واتساب .

الطرازات المذكورة في هذه المقالة

مقالات ذات صلة

هل أنت مستعد لمناقشة المواصفات والجهد والكمية؟

أرسل سوقك المستهدف ومواصفاتك. وسيعود إليك فريق التصدير لدينا بعرض سعر B2B مخصص.

اطلب عرض سعر
المبيعات والتصدير
cason@calliopepump.com
خدمات ما بعد البيع
corleone@calliopepump.com
المكتب الرئيسي
office@calliopepump.com
الهاتف / واتساب
+86 178 0591 6566

نستخدم ملفات تعريف الارتباط

التخزين الأساسي يُبقي الموقع يعمل. لا تُضبط ملفات تعريف الارتباط التحليلية إلا بعد النقر على «قبول». وإذا رفضت، فلن تُضبط أي ملفات تعريف ارتباط تحليلية. إشعار ملفات تعريف الارتباط