Z400Permanent Magnet Variable Frequency Booster Pump

The Z400 is the 0.4 kW stainless booster for whole-house pressure boosting, moving 38 L/min to 35 m through 1-inch ports. Its 9 m suction lift, the joint deepest in the range, reaches low tanks and shallow wells, with a copper impeller and stainless body on a ceramic shaft and bearing. A 3 L/min minimum inlet flow keeps it stable on small draws.

Moc znamionowa
0.4 kW
Maksymalny przepływ
38 L/min
Maksymalna wysokość podnoszenia
35 m
Zasilanie
170 - 260 V, 50/60 Hz
Pobierz kartę katalogową (PDF) Zamów próbkę
9 m Suction LiftCopper ImpellerStainless Body35 m Head170–260 V Wide VoltageUltra-Silent

Kluczowe zalety

  • 9 m suction lift — joint deepest in the range, for low tanks and shallow wells.
  • Copper impeller in a stainless precision-cast body, on a ceramic shaft and bearing.
  • Compact 5.3 kg frame with 1-inch ports, for a standard riser.
  • 3 L/min minimum inlet flow, so the pump stays stable on small draws.

Energy saving of 60% or more against a same-power conventional fixed-speed pump at the same flow/head duty point under constant-pressure conditions.

Dane techniczne

Electrical

Moc znamionowa
0.4 kW
Zasilanie
170 - 260 V, 50/60 Hz

Hydraulic

Maksymalny przepływ
38 L/min
Maksymalna wysokość podnoszenia
35 m
Maximum suction lift
9 m
Hałas
≤ 55 dB
Wlot
1 in (25 mm)
Wylot
1 in (25 mm) (same as inlet)

Construction and environment

Pump body and wetted parts
Stainless steel · Ceramic shaft and bearing
Motor type
Permanent magnet motor with integrated variable frequency drive
Liquid temperature range
5–70 °C, pH 6.5–8.5
Ambient temperature range
0–40 °C, RH max. 85%
Solids in the liquid
No solid particles or fibres (smaller than 0.2 mm)

Model data

Values as published for this model range.

ModelMoc (kW)Moc (HP)Prąd (A)Qmax (L/min)Hmax (m)Suct. max (m)
Z4000.40.552.738359
Z6000.550.75450409

Krzywa wydajności

Wysokość podnoszenia w funkcji wydajności zgodnie z katalogiem, z osiami metrycznymi.

Krzywa wydajności · Z400Wysokość podnoszenia względem wydajności, osie metryczne
0 m10 m20 m30 m40 m45 m0 L/min10 L/min20 L/min30 L/min40 L/min50 L/min55 L/minWydajność Q (L/min)Head H (m)
Z400Z600

Warunki pracy

Limity pracy i warunki medium opublikowane dla tego modelu.

Pompowana ciecz
Clean, thin, non-solidifying, non-flammable and non-explosive liquid
Solids
No solid particles or fibres (smaller than 0.2 mm)
Liquid temperature
5–70 °C, pH 6.5–8.5
Temperatura otoczenia
0–40 °C, RH max. 85%
Max. working pressure
10 bar
Minimum inlet flow
3 L/min
Hałas
≤ 55 dB

Wymiar całkowity

All dimensions in millimetres unless stated otherwise. Dimension references Width a, Height b, Depth c, Port offset d, Port offset e are printed on catalog page 20.

Model Wymiary Waga
Z400
  • Wlot 1"
  • Wylot 1"
  • a 175 mm
  • b 50 mm
  • c 131 mm
  • d 99 mm
  • e 63 mm
  • f 7 mm
  • g 88 mm
  • h 179 mm
5.3 kg
Z600
  • Wlot 1"
  • Wylot 1"
  • a 175 mm
  • b 50 mm
  • c 131 mm
  • d 99 mm
  • e 63 mm
  • f 7 mm
  • g 88 mm
  • h 179 mm
5.3 kg

Zastosowania

Home boosting from low tanks and shallow wells — the 9 m suction lift reaches water other small boosters cannot.

  • Podnoszenie ciśnienia w całym domu
  • Rooftop Tank & Water Tower Boosting
  • Nawadnianie ogrodu

Uwagi dotyczące instalacji

  • Liquid condition: No solid particles or fibres (smaller than 0.2 mm).

Opakowanie

Informacje o pakowaniu opublikowane dla tego modelu.

Opakowanie
Carton with Plywood Tray
Rozmiar kartonu
21.5 × 16.3 × 21 cm
Waga brutto
5.3 kg

Informacje o zamawianiu

Ordering information for this model.

MOQ and packaging
Minimum order quantity (MOQ): 50 units in kraft-paper cartons, with your brand label available. 300 units in color boxes, with the packaging layout designed entirely to your requirements.
Lead time
30 days
OEM / ODM
Supported: custom voltage and frequency builds, own brand nameplate and rating labels, and adapted carton and shipping marks.
Przyłącze
1 in (25 mm)

Warranty: 2 yearsGwarancja i serwis posprzedażowy

Wskazówki doboru

Jak Z400 jest zestawiona z resztą oferty.

  • Choose Z400 for a single dwelling on a tank or shallow well with 9 m suction and up to 35 m of head.
  • Step up to Z600 for longer pipe runs and up to 40 m of head.
  • Keep the inlet flow above 3 L/min and the working pressure within 10 bar.

Zasilanie i oznakowanie CE

Zasilanie i certyfikacja dla tego modelu są wymienione w danych technicznych powyżej. Oferta posiada oznakowanie CE dopuszczające do sprzedaży na terenie Europejskiego Obszaru Gospodarczego; dokumentacja techniczna została zweryfikowana przez ECM, certyfikat nr 0P230414.FMEUN01.

Pliki do pobrania

Karta katalogowa, krzywa wydajności i dane wymiarowe dla tego modelu.

  • kartę katalogową

    Model, key specifications, power stage data and packing details generated from the catalog data on this page.

  • Performance Curve

    Head and flow curve for this model, redrawn from the catalog axis ranges.

  • Dimension Data

    Dimension table for each model in the range, in millimetres and inches.

Praca nad a Z400 projekt? Wyślij punkt pracy, rynek i wolumen, a zespół eksportu potwierdzi konfigurację.

Używamy plików cookie

Niezbędne pliki są potrzebne do działania strony. Pliki cookie analityczne są ustawiane dopiero po kliknięciu „Akceptuj”. W przypadku odmowy nie są ustawiane żadne pliki cookie analityczne. Informacja o plikach cookie