SCS90P SERIES
SCS90P-3PM VFD Multistage Stainless Steel Pump
The SCS90P-3 is the compact stainless multistage pump for homes that want every wetted part in stainless steel — body, impeller and shaft are all stainless, so the water touches no other metal. Five stages from 0.24 to 0.47 kW deliver up to 75 L/min across 25 to 45 m of head, the lowest power band of the stainless multistage models. G 1-inch threaded ports, 7 m of suction lift and a 6.4 kg body make it a small-footprint multistage unit for clean-water boosting on mains or tank supply.
- Moc znamionowa
- 0,24–0,47 kW (regulacja 5-stopniowa)
- Maksymalny przepływ
- 4.5 m³/h (19.8 GPM)
- Maksymalna wysokość podnoszenia
- 45 m (148 ft)
- Zasilanie
- 170 - 250 V, 50/60 Hz
Kluczowe zalety
- 100% stainless wetted path — body, impeller and shaft — so the water touches no other metal.
- Lowest power band of the stainless multistage models: five stages from 0.24 to 0.47 kW.
- 75 L/min across 25–45 m of head, with G 1-inch threaded ports for a standard riser.
- 6.4 kg body with 7 m suction lift for tank supply below the pump.
Compared with a same-power conventional fixed-speed pump at the same flow/head duty point under constant-pressure conditions, energy saving is 60% or more.
Dane techniczne
Electrical
- Moc znamionowa
- 0,24–0,47 kW (regulacja 5-stopniowa)
- Power stages
- 5 adjustable power stages
- Zasilanie
- 170 - 250 V, 50/60 Hz
Hydraulic
- Maksymalny przepływ
- 4.5 m³/h (19.8 GPM)
- Maksymalna wysokość podnoszenia
- 45 m (148 ft)
- Maximum working pressure
- 10 bar (145 psi)
- Maximum outlet pressure
- Inlet pressure + 3.8 bar (55 psi)
- Maximum suction lift
- 7 m (23 ft)
- Wlot
- G 1 in (25 mm)
- Wylot
- G 1 in (25 mm) (same as inlet)
Construction and environment
- Pump body and wetted parts
- Stainless steel
- Motor type
- Permanent magnet motor with integrated variable frequency drive
- Liquid temperature range
- 5 - 70 °C, pH 6.5 - 8.5
- Ambient temperature range
- 0 - 40 °C, humidity up to 85%
- pH range
- pH 6.5 - 8.5
- Solids in the liquid
- No particles or fibres larger than 0.2 mm
- Pompowana ciecz
- Thin, clean, non-solidifying, non-flammable liquid
SCS90P-3 power stage data
Flow and head at each power stage for this model.
| Stopień | Moc (kW) | Power max (kW) | Prąd (A) | Maks. przepływ (L/min) | Maks. wysokość podnoszenia (m) | Ssanie (m) |
|---|---|---|---|---|---|---|
| Power 1 | 0.24 | 0.47 | 5.1 | 75 L/min (4.5 m³/h) | 25 m (82 ft) | 7 m (23 ft) |
| Power 2 | 0.3 | 0.47 | 5.1 | 75 L/min (4.5 m³/h) | 30 m (98 ft) | 7 m (23 ft) |
| Power 3 | 0.38 | 0.47 | 5.1 | 75 L/min (4.5 m³/h) | 35 m (115 ft) | 7 m (23 ft) |
| Power 4 | 0.43 | 0.47 | 5.1 | 75 L/min (4.5 m³/h) | 40 m (131 ft) | 7 m (23 ft) |
| Power 5 | 0.47 | 0.47 | 5.1 | 75 L/min (4.5 m³/h) | 45 m (148 ft) | 7 m (23 ft) |
Krzywa wydajności
Wysokość podnoszenia w funkcji wydajności zgodnie z katalogiem, z osiami metrycznymi i imperialnymi.
Q-H grid data
| Seria | 0 L/min (0 m³/h) | 8 L/min (0.5 m³/h) | 16 L/min (1 m³/h) | 25 L/min (1.5 m³/h) | 33 L/min (2 m³/h) | 42 L/min (2.5 m³/h) | 50 L/min (3 m³/h) | 58 L/min (3.5 m³/h) | 66 L/min (4 m³/h) | 75 L/min (4.5 m³/h) | 78 L/min (4.7 m³/h) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Power 1 (m) | 25 m (82 ft) | 25 m (82 ft) | 25 m (82 ft) | 25 m (82 ft) | 25 m (82 ft) | 25 m (82 ft) | 25 m (82 ft) | 25 m (82 ft) | 25 m (82 ft) | 16 m (52 ft) | 7 m (23 ft) |
| Power 2 (m) | 30 m (98 ft) | 30 m (98 ft) | 30 m (98 ft) | 30 m (98 ft) | 30 m (98 ft) | 30 m (98 ft) | 30 m (98 ft) | 30 m (98 ft) | 25 m (82 ft) | 16 m (52 ft) | 7 m (23 ft) |
| Power 3 (m) | 35 m (115 ft) | 35 m (115 ft) | 35 m (115 ft) | 35 m (115 ft) | 35 m (115 ft) | 35 m (115 ft) | 35 m (115 ft) | 32 m (105 ft) | 25 m (82 ft) | 16 m (52 ft) | 7 m (23 ft) |
| Power 4 (m) | 40 m (131 ft) | 40 m (131 ft) | 40 m (131 ft) | 40 m (131 ft) | 40 m (131 ft) | 36 m (118 ft) | 36 m (118 ft) | 32 m (105 ft) | 25 m (82 ft) | 16 m (52 ft) | 7 m (23 ft) |
| Power 5 (m) | 45 m (148 ft) | 45 m (148 ft) | 45 m (148 ft) | 45 m (148 ft) | 42 m (138 ft) | 38 m (125 ft) | 38 m (125 ft) | 32 m (105 ft) | 25 m (82 ft) | 16 m (52 ft) | 7 m (23 ft) |
Wymiar całkowity
All dimensions in millimetres unless stated otherwise. Dimension references Overall length, Overall height, Base width, Port offset are printed on catalog page 13.
| Model | Wymiary | Waga |
|---|---|---|
| SCS90P-3 |
| 6.4 kg |
Zastosowania
Clean-water home boosting where every wetted part should be stainless — houses that prize water safety and a compact multistage build.
- Wille i domy wielopiętrowe
- Rooftop Tank & Water Tower Boosting
- HVAC System
Uwagi dotyczące instalacji
- Liquid condition: No particles or fibres larger than 0.2 mm.
Opakowanie
Informacje o pakowaniu opublikowane dla tego modelu.
- Opakowanie
- Carton with plywood tray
- Rozmiar kartonu
- 27 × 19.5 × 28 cm
- Waga brutto
- 6.4 kg
Informacje o zamawianiu
Ordering information for this model.
- MOQ and packaging
- Minimum order quantity (MOQ): 50 units in kraft-paper cartons, with your brand label available. 300 units in color boxes, with the packaging layout designed entirely to your requirements.
- Lead time
- 30 days
- OEM / ODM
- Supported: custom voltage and frequency builds, own brand nameplate and rating labels, and adapted carton and shipping marks.
- Przyłącze
- G 1 in (25 mm)
Warranty: 2 yearsGwarancja i serwis posprzedażowy
Zasilanie i oznakowanie CE
Zasilanie i certyfikacja dla tego modelu są wymienione w danych technicznych powyżej. Oferta posiada oznakowanie CE dopuszczające do sprzedaży na terenie Europejskiego Obszaru Gospodarczego; dokumentacja techniczna została zweryfikowana przez ECM, certyfikat nr 0P230414.FMEUN01.
Pliki do pobrania
Karta katalogowa, krzywa wydajności i dane wymiarowe dla tego modelu.
kartę katalogową
Model, key specifications, power stage data and packing details generated from the catalog data on this page.
Performance Curve
Head and flow curve for this model, redrawn from the catalog axis ranges.
Dimension Data
Dimension table for each model in the range, in millimetres and inches.
Praca nad an SCS90P-3 projekt? Wyślij punkt pracy, rynek i wolumen, a zespół eksportu potwierdzi konfigurację.